Kikokotoo hiki kinafuata Mwongozo wa Marejeleo wa HEC-RAS katika kuhesabu n mchanganyiko wa eneo ukitumia Chow 1959, ukurasa 136, mlinganyo 6-17 (si 6-18).
Kifuniko cha mawe
Tumia Kikokotoo cha Mfereji wa Trapezoidi wa Manning kubuni kifuniko cha mawe. Kikokotoo hiki kinafaa zaidi kwa sehemu za asili.
Errata
Found and fixed 23 August 2026. A segment drawn exactly vertical — two points at the same station, one above the other, which is how a rectangular channel, a box culvert or a retaining wall is drawn — added no wetted perimeter. Results from before that date are too high for any section with a vertical wall: a channel 10 wide and 5 deep was given a wetted perimeter of 10 instead of 20, and flow about 1.6 times the correct value. A sloping bank, however steep, was never affected, and neither was a wall standing above the water. If you used this page on a section with a vertical wall, please run it again.
Ukaguzi wa kasi
Kasi ya juu inaonyesha kulikuwa na anguko kubwa la mwinuko lililosababisha nishati mahususi ya juu namna hiyo. Nishati hiyo inaweza kupotea haraka kwenye mapanuko, mapinda, au vizuizi. Thibitisha kwamba hii inafaa kwa eneo husika.